Mechanical Specifications:
Contact Resistance: • 20 milliohm maximum initial • 10 milliohm maximum change per contact after test Contact Force: • 50 grams nominal at full deflection Mechanical Shock (30 G peak, 3 axis): • No discontinuity > 2 nanoseconds • 10 milliohm maximum change per contact after test Mechanical Vibration (7.3 G' rms, with 200 gram heat sink load): • No discontinuity > 2 nanoseconds • 10 milliohm maximum change per contact after test Thermal Shock (-55º to 85º C, 10 cycles): • 10 milliohm maximum after test Humidity (25º to 85º C, 80% to 47% RH, 1000 hours): • 10 milliohm maximum change per contact after test Temperature Storage (90º C, 2000 hours): • 10 milliohm maximum change per contact after test |
Mixed Flowing Gas (mated, 20 days): • 10 milliohm maximum change per contact after test Durability: • 100 cycles minimum Dielectric Withstanding Voltage: • 500V AC Insulation Resistance: • 500V DC Dust Test: • 10 milliohm maximum change per contact after test Power Cycling (20º to 90º C, 2000 cycles): • 10 milliohm maximum change per contact after test Accelerated Thermal Cycling (0º to 100º C, 2000 cycles): • 10 milliohm maximum change per contact after test |
||||||||||||||
|
Electrical Specifications: Inductance: • Less than 0.2 nH mutual Capacitance: • Less than 0.02 pf mutual Resistance: • 9 milliohm nominal Spice model available upon request. |
|
||||||||||||||